Supplier: HAMILTON BONADUZ
Description: PRP-X500 is a superficially porous polymeric anion exchange column designed for the separation, purification and isolation of proteins, peptides and DNA/RNA. The methacrylate polymeric coating of the PRP-X500 provides a more hydrophilic surface, preventing hydrophobic interaction sample losses.

Supplier: HAMILTON BONADUZ
Description: The PRP-X100 is a polymeric column packing for separation of inorganic and organic anions from 10 to 500 ppm. These columns can be used to separate ions at concentrations from 1 to 1000 ppm without suppression or elaborate preconcentration techniques. The highly inert polymeric support resists chemical attack from organic solvents and aqueous buffers (0 - 100% aqueous or organic; pH 1 to 13), effectively lengthening column life.

Catalog Number: (HAMI15934)
Supplier: HAMILTON BONADUZ
Description: Needle, Needle, 20 µl, for CR 700-20 syringes
UOM: 1 * 1 items


Supplier: HAMILTON BONADUZ
Description: These tips are validated to optimise the performance of the Microlab 300 system, offering superior accuracy and precision. When the tips are placed onto the probe, the O-ring on the probe compresses into the tip groove. This design only requires a low insertion force to successfully load a tip, resulting in a more ergonomic experience for the user and enabling long-term use with minimal energy exerted.

Supplier: HAMILTON BONADUZ
Description: RCX-10 carbohydrate analysis columns are designed for the isocratic or gradient separation of carbohydrates. When an isocratic method is used with a conductivity, refractive index, ultraviolet, or pulsed amperometric detector (PAD), mono- and di-saccharides such as glucose, fructose, sucrose and lactose can be quickly determined.

Catalog Number: (HAMI67098-01)
Supplier: HAMILTON BONADUZ
Description: Micropipette, Microlab 300 disposable tip hand probe, tubing kit, incl. 5 ferrules, 5 stainless steel rings, 5 fittings, 5 strain reliefs, 12 gauge tubing and a probe tip
UOM: 1 * 1 items


Catalog Number: (HAMI84611)
Supplier: HAMILTON BONADUZ
Description: Adjustable multi-channel gel loading syringes simplify and speed sample loading of 96 lane gels. The adjustable gel loading syringe (AGLS) allows quick, easy transfer and loading of DNA samples. Eight samples at a time can be transferred directly from a microwell plate with 9 mm spacing to a 96-lane gel with 10,8 mm spacing.
UOM: 1 * 1 items


Supplier: HAMILTON BONADUZ
Description: These headspace syringes feature a unique Glue-Free (GF) needle attachment in combination with a High Dynamic (HD) plunger. They are designed specifically for PAL COMBI–xt® headspace autosamplers. Conventional headspace syringe needles are attached to the syringe glass body using glue (cement). Common problems are detached needles or ghost peaks due to low chemical inertness of the cement to solvents or limited resistance to higher temperature. These problems are addressed with the Glue Free High Temperature (HDHT) headspace syringes.

Supplier: HAMILTON BONADUZ
Description: Neuros™, Needle, Replacement needles for 700/1700 series Neuros™ syringes, Gauge: 33, Length: 77 mm, Type of tip: 3

Supplier: HAMILTON BONADUZ
Description: CTC PAL® autosamplers are able to sample from many different vial and well types and have ultimate platform flexibility. The syringe is the most important part of every injection that the HPLC PAL® system performs. These autosampler syringes are specially designed for use in these HPLC PAL® systems: PAL® HTC-xt, PAL® HTS-xt, PAL® HTX-xt sold under the following brands: AB Sciex, Agilent, Alpha M.O.S., Antek, Bruker, Dionex, GE, Gerstel, GL Sciences, Lauda, LEAP Technologies, MicroCal, MPS, Perichrom, PerkinElmer, Shimadzu, Sotax, Thermo Scientific, Waters and Zoex.

Catalog Number: (HAMI202903)
Supplier: HAMILTON BONADUZ
Description: Needle, Gauge: 26s, Length: 57 mm, Ø ext.: 0,47 mm, Ø int.: 0,13 mm, Type of tip: 5
UOM: 1 * 6 items


Supplier: HAMILTON BONADUZ
Description: Needle, Replacement needle with large RN hub for 250 µl Microlitre™ and Gastight® syringes, Gauge: 25s, Length: 50 mm, Type of tip: 3

Supplier: HAMILTON BONADUZ
Description: PRP-1 polymeric HPLC columns are designed for broad ranging uses, similar to C8 or C18 HPLC materials. They combine the best characteristics of silica-based and polymeric columns resulting in highly inert and long-lasting columns. These columns are ideal for applications that require a high degree of column to column and batch to batch consistency (quality assurance, clinical trials). Unlike C8 or C18 columns, PRP-1 has no stationary phase coating. Since there is no stationary phase to hydrolyse, the column maintains its performance characteristics longer than many C8 or C18 columns.

Supplier: HAMILTON BONADUZ
Description: Thanks to a soft contoured handle and a curved hilt these pipettes rest comfortable in your hand. The slim ejection sleeve is made from a high strength, chemically resistant polymer. The slim design allows the pipette to reach to the bottom of narrow tubes without the need for extended length tips.

Supplier: HAMILTON BONADUZ
Description: Kel-F® hub (KF) needles can be used with Luer Tip (LT) and PTFE Luer Lock (TLL) syringes and connectors. Custom lengths and point styles are available.

Supplier: HAMILTON BONADUZ
Description: Metal hub (nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors. The needles are 304 stainless steel. Custom needle lengths and point styles are available.

Inquire for Price
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us on 0800 22 33 44.
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us on 0800 22 33 44
Additional Documentation may be needed to purchase this item. A VWR representative will contact you if needed.
Additional Documentation may be needed to purchase this item. A VWR representative will contact you if needed.
This product has been blocked by your organisation. Please contact your purchasing department for more information.
The original product is no longer available. The replacement shown is available.
Product(s) marked with this symbol are discontinued - sold till end of stock. Alternatives may be available by searching with the VWR Catalogue Number listed above. If you need further assistance, please call VWR Customer Service on 0800 22 33 44.
113 - 128 of 752
no targeter for Bottom