Methanol ≥99.9%, HiPerSolv CHROMANORM®, PFAS grade for LC-MS
Supplier: VWR Chemicals
Ratings:
(No Reviews)
Total Ratings: 0
Avg. Ratings: 0.0 out of 5
|
Danger
|
Synonyms:
Hydroxy methane
, Methyl alcohol
, Carbinol
, Wood alcohol
Packaged under nitrogen.
92498.320EA
348
GBP
92498.320
Methanol ≥99.9%, HiPerSolv CHROMANORM®, PFAS grade for LC-MS
Methanol
VWR® PFAS grade LC-MS solvents undergo a rigorous use test to ensure suitability for analysis of poly- and perfluoroalkyl substances resulting in an ultra low background of PFAS analytes. Using complementary methods a broad range of PFAS analytes are quantified to their detection limits by LC-MS.
- Specifically tested for PFAS analysis
- Ultra low background solvent for LC-MS analysis of PFAS (poly- and perfluoroalkyl substances)
Formula:
CH₃OH MW: 32.04 g/mol Boiling Pt: 64.6 °C (1013 hPa) Melting Pt: –98 °C Density: 0.7918 g/cm³ (20 °C) Flash Pt: 11 °C (closed cup) Storage Temperature: Ambient |
MDL Number:
MFCD00004595 CAS Number: 67-56-1 EINECS: 200-659-6 UN: 1230 ADR: 3 (6.1),II REACH: 01-2119433307-44 Merck Index: 13,05984 |
Specification Test Results
Assay | min. 99.9% |
Water | max. 0.02% |
Evaporation Residue | max. 0.0001% |
Acidity [meq/g] | max. 0.0003 |
Alkalinity [meq/g] | max. 0.0002 |
Gradient use test (230 nm) | max. 0.002 AU |
Gradient use test (254 nm) | max. 0.002 AU |
Baseline drift (230 nm) | max. 0.02 AU |
Fluorescence (as quinine; 254 nm) | max. 1 ppb |
Fluorescence (as quinine; 365 nm) | max. 1 ppb |
UV transmission (205 nm) | min. 10% |
UV transmission (210 nm) | min. 50% |
UV transmission (225 nm) | min. 80% |
UV transmission (240 nm) | min. 95% |
UV transmission (265-400 nm) | min. 99% |
Ag (Silver) | max. 10 ppb |
Al (Aluminium) | max. 25 ppb |
Ca (Calcium) | max. 25 ppb |
Cu (Copper) | max. 10 ppb |
Fe (Iron) | max. 10 ppb |
K (Potassium) | max. 10 ppb |
Mg (Magnesium) | max. 10 ppb |
Mn (Manganese) | max. 10 ppb |
Na (Sodium) | max. 50 ppb |
Ni (Nickel) | max. 10 ppb |
Pb (Lead) | max. 10 ppb |
Zn (Zinc) | max. 10 ppb |
Suitability for PFAS analysis | passes test |
Suitability for LC-MS | passes test |
manufactured and filled under nitrogen |